Dinamička izdržljivost tibijalnog čavla

Zoričić, Filip (2014) Dinamička izdržljivost tibijalnog čavla. = Fatigue strength of tibial nail. Undergraduate thesis , Sveučilište u Zagrebu, Fakultet strojarstva i brodogradnje, UNSPECIFIED. Mentor: Kodvanj, Janoš.

[img] Text
28_02_2014_Zavrsni_rad_Dinamicka_izdrzljivost_tibijalnog_cavla.pdf - Published Version
Restricted to Repository staff only Jezik dokumenta:Croatian

Download (4MB)

Abstract (Croatian)

Povećanjem prosječne životne dobi stanovništva, i uzimajući u obzir nivo aktivnosti starije populacije, liječenje prijeloma dugih kosti ima sve veći značaj. Usporedno s time, osteoporoza, kao jedna od najučestalijih bolesti starije populacije, no sve više i mlađih osoba, predstavlja značajan javno-zdravstveni i društveno-ekonomski problem. Iz tog razloga sve je veći broj osteoporotičnih trauma i prijeloma goljenične kosti. Otvoreni tibijalni dijafizarni prijelomi i nestabilni zatvoreni prijelomi visoke energije spadaju među neke od češćih osteoporotičnih prijeloma i trauma. Takvi prijelomi se danas operativno uglavnom liječe medularnom osteosintezom pomoću intramedularnog tibijalnog čavla. U ovom radu eksperimentalno je ispitan tibijalni čavao pri statičkom i cikličkom savijanju u četiri točke. Ispitivanja su provedena prema normi ASTM F1264-03 s kratkim i dugim čavlima proizvedenim iz titana i nehrđajućeg čelika. Iz rezultata je vidljivo da su manji progibi, odnosno veća krutost čavla proizvedenih od nehrđajućeg čelika. Lom kratkog tibijalnog čavla od medicinskog čelika prije traženog broja ciklusa ukazuje na to da implantati od titana imaju veću dinamičku izdržljivost. Uz eksperimentalna ispitivanja provedene su i računalne simulacije statičkog ispitivanja metodom konačnih elemenata u programskom paketu _Abaqus_.

Abstract

By increasing the average age of the population, and taking into account the activity level of the elderly population, treatment of fractures of the long bones has increasing importance. Comparatively with this, osteoporosis, as well as one of the most common dieases of the eldery population, but becoming more among young people also, is starting to represent significant public health and socio-economic problem. For this reason, there is increase in number of osteoporotic fractures and trauma tibia Open tibial diaphyseal fractures and unstable closed high-energy fractures, are among some of the more common osteoporotic fractures and traumas. Such fractures are usually treated today with medullary osteosynthesis using intramedullary tibial nail. This paper experimentally examined tibial nail under static and cyclic bending in four points. Tests were performed in accordance with ASTM F1264-03 on short and long nails manufactured from titanium and stainless steel. The results show that small deflections, respectively greater rigidity are by nails manufactured of stainless steel. Fracture short tibial nail of medical steel before the required number of cycles indicates that titanium implants are more dynamic endurance. Along with experimental testings computer simulations of static tests were made in the software package Abaqus.

Item Type: Thesis (Undergraduate thesis)
Uncontrolled Keywords: čavao; dinamičko ispitivanje; dinamička savojna izdržljivost; krutost
Keywords (Croatian): tibial nail, dynamic testing, dynamic bending endurance, stiffness
Divisions: 200 Department of Engineering Mechanics > 220 Chair of Experimental Mechanics
Date Deposited: 22 Sep 2014 18:00
Last Modified: 16 Oct 2015 12:49
URI: http://repozitorij.fsb.hr/id/eprint/2693

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

Nema podataka za dohvacanje citata