Pavić, Andrej and Kodvanj, Janoš and Sabalić, Srećko and Čukelj, Fabijan and Bakota, Bore (2013) Novel external fixation fracture method with circular locking mechanism compared with the application of dynamic axial external fixator on experimental tibial model ensures better stability in bending and favourable performance in dynamic loads. = Novel external fixation fracture method with circular locking mechanism compared with the application of dynamic axial external fixator on experimental tibial model ensures better stability in bending and favourable performance in dynamic loads. Injury, 44 (SUPPL.). S52-S55. ISSN 0020-1383. Vrsta rada: ["eprint_fieldopt_article_type_article" not defined]. Kvartili JCR: Q3 (2013). Točan broj autora: 5.
|
Text
Novel_Kodvanj.pdf - Accepted Version Jezik dokumenta:English Download (2MB) | Preview |
Abstract
Objective The aim of this study was to compare the biomechanical properties of a novel tibial external bone fracture fixator with a circular locking mechanism with standard dynamic axial external fixator. Material and Methods In order to investigate the prototype usability in experimental conditions, a biomechanical study was performed in which 42 polyacetal tubes set in 14 experimental groups and subgroups represented the fractured tibia that were fixed by a standard dynamic axial external fixator and a novel fixator. Displacements under static and dynamic loads were measured, with static ones corresponding to three directions of fragment movement and dynamic simulating the human gait. Analysis was performed in SPSS v13, with significance set at P<0.05. Results The novel fixator showed biomechanical superiority in "fragments apart" study groups, while the standard dynamic axial external fixator outperformed the novel one in the situations of bending with "fragments in contact" study groups. There were no significant differences in dynamic load, despite better numerical result of the novel fixator. Conclusion The novel fixator is expectedly faster applicable and offers greater extent of external fixation flexibility. Further developments of this model thus seems justified in both construction improvement and on clinical application.
Item Type: | Article (["eprint_fieldopt_article_type_article" not defined]) |
---|---|
Keywords (Croatian): | article; biomechanics; external fixator; fracture external fixation; gait; priority journal; tibia fracture; biomechanics; comparative study; Croatia; devices; equipment design; external fixator; fracture fixation; human; mechanical stress; procedures; Tibial Fractures; Biomechanical Phenomena; Croatia; Equipment Design; External Fixators; Fracture Fixation; Humans; Stress; Mechanical; Tibial Fractures |
Subjects: | TECHNICAL SCIENCE > Mechanical Engineering BIOMEDICINE AND HEALTH > Basic medical sciences |
Divisions: | 200 Department of Engineering Mechanics > 220 Chair of Experimental Mechanics |
Indexed in Web of Science: | Yes |
Indexed in Current Contents: | Yes |
Citations JCR: | 0 (22.11.2016.) |
Quartiles: | Q3 (2013) |
Date Deposited: | 11 May 2015 12:37 |
Last Modified: | 22 Nov 2016 14:27 |
URI: | http://repozitorij.fsb.hr/id/eprint/4023 |
Actions (login required)
![]() |
View Item |