Razvoj metodologije ultrazvučne kontrole podvodnih konstrukcija

Markučič, Damir (1998) Razvoj metodologije ultrazvučne kontrole podvodnih konstrukcija. = Doctoral thesis , Sveučilište u Zagrebu, Fakultet strojarstva i brodogradnje, UNSPECIFIED. Mentor: Krstelj, Vjera.

Full text not available from this repository.

Abstract (Croatian)

Predmet ovog istraživanja je usporedba rezultata ultrazvučnog ispitivanja pod vodom i "na suhom", u cilju spoznaje granica unutar kojih se rezultati rasipaju. Mjerenja amplitudnih odziva dviju osnovnih vrsta reflektora provedena su kontaktnom ultrazvučnom tehnikom na etalonu i dva uzorka. Analizirani su utjecajni čimbenici karakteristični za podvodnu ultrazvučnu kontrolu: različite duljine koaksijalnih kabela, hrapavosti površine i uvjeti kontakta. U analizi rezultata pokusa korištene su sljedeće metode: statistička analiza preciznosti mjerenja, analiza promjene uvjeta ponovljivosti i obnovljivosti mjerenja primjenom kriterija kritičnih razlika, to analiza varijance. Za potrebe tumačenja rezultata provedena su mjerenja parametara hrapavosti površine i analiza mikrostrukture u vertikalnim presjecima mjernih točaka. Analitički je izveden algoritam za proračun granica povjerenja pri procjeni ekvivalentne veličine detektiranih nepravilnosti. Primjenom algoritma poka7.ano je da se pri mjerenjima pod vodom i s različitim duljinama kabela, procijenjene veličine nepravilnosti značajno razlikuju. Budući da su se rezultati mjerenja prigušenja ultrazvuka u materijalu uzoraka na različitim razinama utjecajnih čimbenika značajno razlikovali provedena su dodatna mjerenja parametara odašiljačkog impulsa. Prikazan je utjecaj različitih duljina kabela na amplitudu i vrijeme trajanja odašiljačkog impulsa. \Na danim razinama čimbenika analizirani su i amplitudno frekvencijski spektri odagi1jadkog impulsa i signala odjeka.

Abstract

The object of this research is the comparison of the ultrasonic testing results obtained under the water and "in dry conditions", in order to find the limits within which the results disperse. The amplitude responses of the two basic types of reflectors have been measured by contact ultrasonic technique on the calibration block and two samples. The influencing factors characteristic for the underwater ultrasonic control, such as various lengths of the coaxial cables, surface roughness. and conditions of contact, have been analysed. The following methods have been used in the analysis of the experimental results: the statistical analysis of the measuring accuracy, analysis of the changes in the repeatability and reproducibility conditions by using the criterion of critical differences, and the analysis of variance. In order to provide the interpretation of results, the surface roughness parameters have been measured and the microstructure at vertical cross-sections of measuring points analysed. The algorithm for calculating the confidence limits in estimating the equivalent discontinuity size has been developed analytically. The application of the algorithm has shown that there are significant differences in the estimated discontinuity values in underwater measurements and with various cable lengths. Because of the significant differences between the results of measuring the ultrasound attenuation in sample materials at various levels of influencing factors, additional measurements of the pulse signals have been performed. The influence of various cable lengths on the amplitude and duration of the pulse signal has been presented. Also, the amplitude frequency spectra of the pulse and echo signals have been analysed at the given factor levels.

Item Type: Thesis (Doctoral thesis)
Uncontrolled Keywords: podvodna nerazorna ispitivanja; podvodna ultrazvučna kontrola; pomorske konstrukcije; procjena sposobnosti ispitnih sustava; ponovljivost I obnovljivost; procjena ekvivalentne veličine reflektora
Divisions: 800 Department of Quality > 820 Chair of Non-Destructive Testing
Date Deposited: 22 Sep 2014 18:00
Last Modified: 20 Apr 2017 12:15
URI: http://repozitorij.fsb.hr/id/eprint/89

Actions (login required)

View Item View Item

Nema podataka za dohvacanje citata